Revision to Test and calibrate the Z probe

Tony

# Jog the head up by 5 to 10mm
# If the Z probe needs to be deployed, deploy it
# Send command G30 S-1. The nozzle will descend or the bed rise until the probe triggers and the Z height at which the probe stopped will be reported. If you are using a nozzle-contact Z proveprobe, the trigger height will be slightly negative. For any other type of Z probe where the proveprobe triggers before the nozzle conrtactscontacts the bed, it will be positive.
# Send command G30 S-1. The nozzle will descend or the bed rise until the probe triggers and the Z height at which the probe stopped will be reported. If you are using a nozzle-contact Z proveprobe, the trigger height will be slightly negative. For any other type of Z probe where the proveprobe triggers before the nozzle conrtactscontacts the bed, it will be positive.
# Repeat from step 5 two or three times to make sure that the trigger height is consistent.
# In Duet Web Control, go to Settings -> System Editor and edit the config.g file. Set the Z parameter in the G31 command tto the trigger height that was reported. Save the file.
# In Duet Web Control, go to Settings -> System Editor and edit the config.g file. Set the Z parameter in the G31 command tto the trigger height that was reported. Save the file.
 
== More information on Z Probes ==

To undo the changes made by this version, click 'Revert Changes.' This will automatically restore the previous version of this guide.

Revert Changes