Revision to M303

Александр Пивоваров

[title|M303]
+
+[summary]08.10.2021
+
+Just removed misspell
+
+Ynn (RRF 3.3beta3 and laterm optional) <----here[/summary]
* ***Tnnn*** (RRF 3.2 and later, optional) Tool whose primary heater is to be tuned
* ***Annn*** (RRF 3.2 and later, optional) ambient temperature - use this parameter if you want to tune a heater that has been on and has not cooled down to ambient temperature yet
-* ***Ynn*** (RRF 3.3beta3 and laterm optional) Tuning cycle hysteresis, default 5C. When tuning bed heaters that are slow to cool down, tuning will be faster if you use a lower value, provided that there is no noise in the temperature readings.
+* ***Ynn*** (RRF 3.3beta3 and later optional) Tuning cycle hysteresis, default 5C. When tuning bed heaters that are slow to cool down, tuning will be faster if you use a lower value, provided that there is no noise in the temperature readings.
* ***F***nn (RRF 3.3beta3 and later) Fan PWM to use when the print cooling fan is turned on (ignored if the T parameter is not present), default 1.0. Use a lower value if youpr printer uses a powerful print cooling fan that you do not normally run at full PWM.