Tony

* ***S*** Maximum permitted temperature
* ***P*** Heater monitor number, default 0
-* ***T*** Sensor number used to monitor the heater. It default to the sensor that controls the heater (as was specified in the M305 command when the heater was created).
+* ***T*** Sensor number used to monitor the heater. It default to the sensor that controls the heater (as was specified in the M950 command when the heater was created).
* ***A*** Action to trigger (0: Generate heater fault [default] 1: Switch off permanently 2: Switch off temporarily 3: Shut down the printer)^^1^^
* ***C*** Condition for temperature event (0: Temperature too high [default] 1: Temperature too low, -1: Monitor is disabled)